®MODEL A-100NV Variable SpeedPeristaltic Injector PumpOperating Manual5300 Business DriveHuntington Beach, CA 92649USAPhone: 714-893-8529 FAX: 714-894
6.2 OPERATING MODE 1 - Output adjusted manually - In this mode, the pump’s motor speed is adjusted manually using the front panel touch pad. The motor
Page 11PROGRAM MODE 2% speed at the minimum inputRUNPROGRAMSTAND-BYPRIMEMINIMUMMAXIMUM% SPEED2MODE000input value. 4Enter the programming mode. At the
4Repeat until all digits are programmed.4Press the mode button. Programming is complete.4To exit the programming mode, press the RUN/STANDBY button an
PROGRAM MODE 3minimum input valueRUNPROGRAMSTAND-BYPRIMEMINIMUMMAXIMUM3MODE00.0VDC4Enter the motor speed at the minimum VDC input signal value. Press
6.5 - OPERATING MODE 4 - Output adjusted by frequency (Hz) input signal In this mode, the pump’s motor speed is adjusted automatically based on the fr
PROGRAM MODE 4minimum input valueRUNPROGRAMSTAND-BYPRIMEMINIMUMMAXIMUM4MODE620Hzcurrently programmed maximum motor speed value is shown on the 3-DIGIT
7.0 ALARMS - 7.1 TFD - Tube Failure Detection system - The A-100NV is equipped with a Tube Failure Detection System which is designed to stop the pump
Confirm the FVS flow range - The Flow Verification Sensor (FVS) will only function within its operating range. Sensor model FV-100-6V has an operating
Page 188.0 How to Maintain the Pump8.1 Routine Inspection and MaintenanceThe pump requires very little maintenance. However, the pump and all accesso
Page 19Remove the Old Pump Tube - The pump roller assembly spins in a counter clockwise direction. The pump head inlet (suction) side is located at th
A-100NVPage 2TABLE OF CONTENTS1...Introduction...22...Specificati
Page 20REPLACEMENT PARTS DRAWING491516113133137383945484640303212954575610123664BRUSH KIT2081841282914LDFIEGDITIODMEANYSDBTIMPRERSEET9ECCL9S.CYEBLWARI
Page 21REPLACEMENT PARTS LISTItem Part No Description Qty1 71000-489 Enclosure Back Plate With Gasket, Valox 12 90011-094 Washer, Mounting, #10 Stainl
LIMITED WARRANTYYour new pump is a quality product and is warranted to be free of defects as set down in this policy. All parts, including rubberized
ARKANSAS American PumpBT Environmental, Inc 7580-A W. Tennessee St. NORTH CAROLINABill Thomason Tallahassee, FL 32304 Southern Industrial Sales 225 Ca
# 80000-381 Rev. 3/8/20065300 Business DriveHuntington Beach, CA 92649USAPhone: 714-893-8529 FAX: 714-894-9492E mail: [email protected] or tech
A-100NV Page 32.0 SpecificationsMaximum Working Pressure 100 psig / 6.9 bar (most models)o o Maximum Fluid Temperature 130 F / 54 Co oAmbient Tempera
Page 45.0 InstallationNote: All diagrams are strictly for guideline purposes only. Always consult an expert before installing the pump into specialize
Page 5TYPICAL INSTALLATIONRSuctionTubeChemicalContainerwith coverRUNSTANDBYRUNFIELDDIGIT MODEPROGRAMSTAND-BYPRIMEMINIMUMMAXIMUMINPUTMODES1-MANUAL2-4-2
Page 65.3 External Input Signal Connections The A-100NV will accept any one of three different types of external input signals; 4-20 mA , 0-10 VDC, or
Page 7 CIRCUIT BOARD CONNECTIONSAC sine wavesJumper Not Installed(open - factory default)Digital square wavesJumper InstalledDCMOTORBLACK (-)RED (+)G
Page 85.4 How To Install the Tubing and Fittings! Inlet Tubing - Locate the inlet fitting of the Pump Tube. Remove the tube nut. Push the clear PVC
Page 96.0 How To Operate The A-100NV6.1 Description of Pump Output Adjustment Controls - Open the control panel door by sliding the upper and lower sl