Xylem FC220 OPEN CHANNEL FLOW MONITOR Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Outils Xylem FC220 OPEN CHANNEL FLOW MONITOR. Xylem FC220 OPEN CHANNEL FLOW MONITOR User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 23
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Global Water
800-876-1172 globalw.com
- 1 -
Global Water
Instrumentation, Inc.
151 Graham Road
P.O. Box 9010
College Station, TX 77842-9010
T: 800-876-1172
Int’l: (979) 690-5560, F: (979) 690-0440
E-mail : globa[email protected]
FC220 Flow Monitor
02-056
Publication Number 38580512
Vue de la page 0
1 2 3 4 5 6 ... 22 23

Résumé du contenu

Page 1 - Global Water

Global Water 800-876-1172 • globalw.com - 1 - Global Water Instrumentation, Inc. 151 Graham Road P.O. Box 9010 College Station, TX 778

Page 2

Global Water 800-876-1172 • globalw.com - 10 - VIII. Power Saving Mode A power saving mode is provided that allows the operating current to be r

Page 3

Global Water 800-876-1172 • globalw.com - 11 - 5 selectable volume units. The engineering notation is automatically switched on when the totalize

Page 4

Global Water 800-876-1172 • globalw.com - 12 - Set Volume Unit: This unit is used to display the totalizer volume on the main display. The cur

Page 5

Global Water 800-876-1172 • globalw.com - 13 - RIGHT arrow to move to the level unit, the units will flash. Use UP and DOWN to select the unit th

Page 6

Global Water 800-876-1172 • globalw.com - 14 - Set Site Info: The Site Info menu is where the type of flow monitor calculation is defined. A 16

Page 7

Global Water 800-876-1172 • globalw.com - 15 - width of the rectangular channel. Use the RIGHT arrow to advance to the units until they flash, us

Page 8

Global Water 800-876-1172 • globalw.com - 16 - Power Saving Mode: The power saving mode allows the average power consumption to be reduced by con

Page 9

Global Water 800-876-1172 • globalw.com - 17 - Totalizer Reset: The Totalizer Reset menu allows the totalizer to be reset to zero. The reset

Page 10

Global Water 800-876-1172 • globalw.com - 18 - XIII. Maintenance and Troubleshooting a. Global Water recommends verifying the sensor’s calibrat

Page 11

Global Water 800-876-1172 • globalw.com - 19 - See Appendix A. Warning: Always connect the sensor with the power turned off. At zero feet (out

Page 12

Global Water 800-876-1172 • globalw.com - 2 - Congratulations on your purchase of the Global Water FC220 Flow Monitor. This instrument has been

Page 13

Global Water 800-876-1172 • globalw.com - 20 - Send the package with shipping prepaid to our factory address. Insure your shipment, Global Water’

Page 14

Global Water 800-876-1172 • globalw.com - 21 - XIV. Appendix A: Terminal Strip Diagram POWER IN: V+ 12VDC or 18-24VDC Input V+

Page 15

Global Water 800-876-1172 • globalw.com - 22 - XV: Appendix B: Flume and Weir Equation Parameters EQ Type: 1 = Flow 2 = Poly Q=A*(

Page 16

Global Water 800-876-1172 • globalw.com - 23 - Weirs EQ Type A B C D 1.0' Rectangular 1 3.333 0.000000 1 1.500 2.0' Rectangular

Page 17

Global Water 800-876-1172 • globalw.com - 3 - I. FC220 Flow Monitor Description The Global Water FC220 Flow Monitor is a reliable and accurat

Page 18

Global Water 800-876-1172 • globalw.com - 4 - Four independent relay outputs are provided for triggering external devices like water samplers and

Page 19

Global Water 800-876-1172 • globalw.com - 5 - II. FC220 Specifications: Power Requirements: 12VDC or 18-24VDC Input, +/-10% Supply Current: 1

Page 20

Global Water 800-876-1172 • globalw.com - 6 - III. Flow Calculation Modes The FC220 determines flow from water level in several different ways.

Page 21

Global Water 800-876-1172 • globalw.com - 7 - In these modes the user is either prompted to enter the pipe diameter or rectangular channel width,

Page 22

Global Water 800-876-1172 • globalw.com - 8 - IV. Switch Settings Inside the FC220 is a bank of 8 switches which are used to select the sensor

Page 23

Global Water 800-876-1172 • globalw.com - 9 - V. Sensor Input The FC220 accepts any water level sensor with a 4-20mA, 0-5VDC or 0-1VDC output.

Commentaires sur ces manuels

Pas de commentaire