Xylem CR500 CIRCULAR CHART RECORDERS Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Outils Xylem CR500 CIRCULAR CHART RECORDERS. Xylem CR500 CIRCULAR CHART RECORDERS User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 33
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Global Water
800-876-1172 globalw.com
- 1 -
Global Water
Instrumentation, Inc.
11390 Amalgam Way
Gold River, CA 95670
T: 800-876-1172
Int’l: (916) 638-3429, F: (916) 638-3270
Circle Chart Recorder: CR500
Vue de la page 0
1 2 3 4 5 6 ... 32 33

Résumé du contenu

Page 1 - Global Water

Global Water 800-876-1172 • globalw.com - 1 - Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int’l: (9

Page 2

Global Water 800-876-1172 • globalw.com - 10 - Thermocouple (TC) Installation Guidelines Proper sensor installation can eliminate many problems in a

Page 3 - Table of Contents

Global Water 800-876-1172 • globalw.com - 11 - plate. If you are not sure how to access the back of the chart plate, please contact GLOBAL WATER INS

Page 4 - Overview

Global Water 800-876-1172 • globalw.com - 12 - Fig. 2.6 Two Pen Universal and Thermal Inputs

Page 5 - Installation

Global Water 800-876-1172 • globalw.com - 13 - RTD Input Wiring RTD connections are shown in the previous, with the compensating lead connected to t

Page 6

Global Water 800-876-1172 • globalw.com - 14 - Changing the Chart Press and release the CHANGE CHART key (3 on Figure 2.7). The pen(s) will move to

Page 7

Global Water 800-876-1172 • globalw.com - 15 - Replacement of Pen “Ink Type” Recorders that are equipped with fiber tipped cartridge pens are colo

Page 8

Global Water 800-876-1172 • globalw.com - 16 - 3. Follow the thermal pen leads to the main “mother” board located on the back of the recorder plate

Page 9

Global Water 800-876-1172 • globalw.com - 17 - NOTE: Units with optional display. Display will go BLANK upon AC power loss. Figure 2.10 Recorder

Page 10

Global Water 800-876-1172 • globalw.com - 18 - III) Programming Recorder Setup - "Single Pen Ink Type" In order to configure the recorde

Page 11

Global Water 800-876-1172 • globalw.com - 19 - Recorder Setup - Dual Pen (Universal) Input Ink Style In order to configure the recorder, you will

Page 12

Global Water 800-876-1172 • globalw.com - 2 - Warning Symbol This Symbol calls attention to an operating procedure, practice, or the like, w

Page 13

Global Water 800-876-1172 • globalw.com - 20 - 1. Disconnect power from the unit to be configured. 2. To configure unit for single channel operati

Page 14

Global Water 800-876-1172 • globalw.com - 21 - Alarm Settings Ink Style Recorders Alarm setpoint values are selected by positioning the pen to the

Page 15

Global Water 800-876-1172 • globalw.com - 22 - Alarm Settings Thermal Style Recorders Thermal alarm relay settings can only be set or reviewed

Page 16

Global Water 800-876-1172 • globalw.com - 23 - Alarm Settings Display Option Features The single red LED display indicates input(s) process variabl

Page 17

Global Water 800-876-1172 • globalw.com - 24 - IV) Calibration - Ink Type Only Pen Arm Calibration (Zero and Span) Pen calibration applies to ink t

Page 18 - Programming

Global Water 800-876-1172 • globalw.com - 25 - Probe Offset Adjust - Ink Style (Pen Offset) This recorder has been accurately calibrated at the fact

Page 19

Global Water 800-876-1172 • globalw.com - 26 - Probe Offset - Thermal Style (Pen Offset) This recorder has been accurately calibrated at the factory

Page 20

Global Water 800-876-1172 • globalw.com - 27 - V) Specifications Power Line Voltage: 110/220VAC, 50/60Hz Power Consumption: 15VA maximum Battery B

Page 21

Global Water 800-876-1172 • globalw.com - 28 - 5-1 Input Range Table: Type Range Color Code Polarity J -130° C / 760° C (-202° F

Page 22

Global Water 800-876-1172 • globalw.com - 29 - VI) Default Settings FACTORY SET DEFAULTS Defaults settings are identical for 1 and 2 pen ink or the

Page 23

Global Water 800-876-1172 • globalw.com - 3 - Table of Contents I) OVERVIEW...

Page 24 - Calibration - Ink Type Only

Global Water 800-876-1172 • globalw.com - 30 - VII) Troubleshooting GREEN LED LIGHT SEQUENCE GUIDE 1. LED on steady and pen(s) within chart rang

Page 25

Global Water 800-876-1172 • globalw.com - 31 - c. When calling for tech support, please have the following information ready; 1) Model #. 2) Uni

Page 26

Global Water 800-876-1172 • globalw.com - 32 - IX) Appendix A Spare Parts Red Pens (6pcs/pk) P/N CP400 (Pen 1 ) Blue Pens (6pcs/pk) P/N CP401 (Pe

Page 27 - Specifications

Global Water 800-876-1172 • globalw.com - 33 - X) GLOSSARY: Input Averaging - The number of input readings (in seconds) held and averaged as pen i

Page 28

Global Water 800-876-1172 • globalw.com - 4 - I) Overview General The CR500 is a microprocessor based circle chart recorder. Programmable alarm op

Page 29 - Default Settings

Global Water 800-876-1172 • globalw.com - 5 - II) Installation Dangerous voltages capable of causing death are sometimes present when wiring the i

Page 30 - Troubleshooting

Global Water 800-876-1172 • globalw.com - 6 - Mounting Make panel cutout to dimension shown in Figure 2.0. Install both mounting clamps and insert

Page 31 - Warranty

Global Water 800-876-1172 • globalw.com - 7 - Wiring Precautions 1) Before wiring, verify the label for correct model number and options. Switch of

Page 32

Global Water 800-876-1172 • globalw.com - 8 - to access the back of the chart plate, please contact GLOBAL WATER INSTRUMENTATION before continuing.

Page 33

Global Water 800-876-1172 • globalw.com - 9 - 4-20mA Input Wiring Pen1/Pen2 Transmitters and sensors with 4-20mA outputs can also be connected to t

Commentaires sur ces manuels

Pas de commentaire