ModelH-310Owner's ManualNOTICEThis product embodies technology that is confidential and proprietary technology of DESIGNANALYSIS ASSOCIATES, INC.
1-2 Unpacking the H-310 H-3101.2 Checking the Model NumberBefore installing your new WATERLOG® H-310, check the information on the label of the sens
Chapter 2InstallationH-310 Installation 2-12.1 Installing the WATERLOG® H-310 and the H-305To install the WATERLOG® H-310 sensor and the H-305 dry ai
2-2 Installation H-310Figure 2-13. The H-305 dry air system should be placed in an easily accessible spot. This allows the user tomaintain the desicc
H-310 Installation 2-32.1.2 Environmental ConcernsThrough years of experience dealing with measuring in the environment, we have learned thatMother N
2-4 Installation H-3102.4 Connecting the Hook-up CableIf the hook-up cable from the junction box to your data recorder needs to be modified orchanged
H-310 Installation 2-5Figure 2-2Step 5- With a small screw driver, loosen the screw of the terminal strip to open each slot whereyou want to insert a
2-6 Installation H-3102.5 Connecting Your Data RecorderYour selected data recorder must be capable of reading the type of signals (SDI-12 or RS-232)o
Chapter 3OperationH-310 Operation 3-13.1 OperationThe WATERLOG® H-310 is easy to use and works with many data recorders. Its internalmicroprocessor
3-2 Operation H-3103.2 Reading Data from the H-310Since data recorders differ widely, you must prepare your data recorder to receive and display theH
Chapter 4MaintenanceH-310 Maintenance 4-14.1 MaintenanceSustained operation is almost maintenance-free. Our experience tells us moisture creates the
4-2 Maintenance H-310Figure 4-1 H-305 Dry Air System4.3 Cleaning the Port ScreenOccasionally the port screen and the pressure ports may need to be c
H-310 Maintenance 4-3Figure 4-2 H-310 Nose piece/Stainless steel screenStep 4- Rinse the pressure ports with water to clear mud and silt. You may wa
4-4 Maintenance H-3104.4 Maintaining Desiccant PacksThe desiccant inside the dry air system should be checked every 3 to 6 months. The desiccantbags
Appendix ASpecificationsH-310 Appendix A Specifications A-1Accuracy(Maximum percent of error in measurement)Pressure: Less than or equal to 0.02% of
Appendix BKey to the Model Ordering SystemH-310 Appendix B Key to the Model Ordering System B-1H-310 - 0 1 5- G I - D - 0 1 0 0
Appendix CSDI-12 Command and Response ProtocolH-310 Appendix C SDI-12 Command and Response Protocol C-1C.1 SDI-12 Command and Response ProtocolThis
C-2 Appendix C SDI-12 Command and Response Protocol H-310C.2 Initiate Measurement Command Command Response Description "aM!"
H-310 Appendix C SDI-12 Command and Response Protocol C-3 C.3 INITIATE VERIFY COMMAND Command Response Description "aV!
Table of ContentsUser Agreement/WATERLOG® Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W-1Preface: A Mes
C-4 Appendix C SDI-12 Command and Response Protocol H-310The Send Data command returns sensor data generated as the result of previous "aM!"
H-310 Appendix C SDI-12 Command and Response Protocol C-5C.6 Send Identification Command Command Response "aI!"
Appendix DH-310 Extended CommandsH-310 Appendix D H-310 Extended Commands D-1D.1 Change Sensor Address Command Response Description "aXAn!&qu
D-2 Appendix D H-310 Extended Commands H-310D.2 Zero Offset Command Command Response Description "aXZ!" "attt
H-310 Appendix D H-310 Extended Commands D-3D.3 Write "User Units Slope" Command Command Response Description "
D-4 Appendix D H-310 Extended Commands H-310D.4 Write "User Units Offset" Command Command Response Description &qu
H-310 Appendix D H-310 Extended Commands D-5D.5 Read "User Units Slope" Command Command Response Description "aXRS!"
D-6 Appendix D H-310 Extended Commands H-310buffer. With the data in the sensor data buffer now you can view the current slope by issuing a"D&q
H-310 Appendix D H-310 Extended Commands D-7 Command Response Description "aXSF!" "a<cr><lf>" Set
Appendix D - H-310 Extended CommandsD.1 Change Sensor Address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
User Agreement/WATERLOG® WarrantyH-310 User Agreement/WATERLOG® Warranty W-11. NATURE OF THE PRODUCTThis agreement accompanies a pressure measuring
W-2 User Agreement/WATERLOG® Warranty H-3104. TERMUSER may enjoy these rights only as long as their possession of the PRODUCT shall continue tobe r
H-310 User Agreement/WATERLOG® Warranty W-3(iii) EXCEPT FOR THE EXPRESS WARRANTIES ABOVE, DESIGNANALYSIS SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES
Chapter 1Unpacking the H-310H-310 Unpacking the H-310 1-1Figure 1-11.1 Unpacking the H-310The following is a list of items you should have received: